SECTION 11: USER INSTRUCTIONS
11.1 User Instructions
The UHD[X][S][R] Series heaters are fully automatic 
and operate from the external controls fitted on site. 
The only user control at the heater is the Manual
Reset Limit Switch - See Page 26, Section 11.3.1
11.2 Heater Operation
When the heater has been switched on by the 
thermostat installed on site, the main burner will 
automatically turn on.
The burner control box will control the safe ignition 
of the flame.
All heaters require a constant gas and electricity 
supply which must not be interrupted during the 
normal operation of this heater.
11.3 Common User Controls
11.3.1 Manual Reset Limit Switch
The limit thermostat is located inside the access 
door of the heater. See Page 37, Section 14.3. This 
control protects against excessive heat build-up 
inside the burner compartment.
Figure 15: Manual Reset Limit Switch
11.4 Lighting Instructions 
11.4.1 To Turn On Heater
1. Ensure that the electrical and gas supplies to 
the heater are on. Check that the on site 
controls are "ON".
IMPORTANT: The thermostat setting must be above 
the ambient temperature for the heater to operate.
2. The automatic firing sequence will begin as 
described on Page 24, Figure 13. The heater 
will now operate automatically under the control 
of the on site controls.
WARNING
Explosion Hazard
Installation, service and annual inspection 
must be done by a contractor qualified in 
the installation and service of gas-fired 
heating equipment or your gas supplier.
Turn off gas and electrical supplies before 
performing service or maintenance.
Failure to follow these instructions can 
result in death, injury or property damage.
WARNING
Explosion Hazard
Do not make more than one attempt to 
restart the heater if manual reset limit switch 
locks out.
The vent or heat exchanger may be blocked.
The fault must be traced and repaired.
Failure to follow these instructions can 
result in death, injury or property damage.
Reset Button
To reset manual reset limit switch, press reset 
button. NOTE: To reset, the switch must be cool.
Description
Part Number
Manual Reset Limit Switch
90412106