Heat & Glo  •  8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI  •  2058-900  Rev. L  •  08/08
MODELS:  8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI
LABORATORY:   Underwriters Laboratories, Inc. (UL)
TYPE:    B-Vent Decorative
STANDARD:   ANSI Z21.50-2002 • CGA2.2
B. Glass Specifi cations
Hearth & Home Technologies appliances manufactured with 
tempered glass may be installed in hazardous locations 
such as bathtub enclosures as defi ned by the Consumer 
Product Safety Commission (CPSC). The tempered glass 
has been tested and certifi ed to the requirements of ANSI 
Z97.1
 and CPSC 16 CFR 1202 (Safety Glazing Certifi cation 
Council SGCC# 1595 and 1597. Architectural Testing, Inc. 
Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR 
Section 1201.5 
“Certifi cation and labeling requirements” 
which refers to 15 U.S. Code (USC) 2063 stating “…Such 
certifi cate shall accompany the product or shall otherwise 
be furnished to any distributor or retailer to whom the 
product is delivered.”
Some local building codes require the use of tempered 
glass with permanent marking in such locations. Glass 
meeting this requirement is available from the factory. 
Please contact your dealer or distributor to order.
A. Appliance Certifi cation
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. 
This appliance is tested and approved as either supplemental 
room heat or as a decorative appliance. It should not be 
factored as primary heat in residential heating calculations.
C. BTU Specifi cations
This product is listed to ANSI standards for “Vented Gas 
Fireplaces” and “Gas Fired Appliances for Use at High 
Altitudes”.
This model (natural gas and propane) can be installed in 
a bedroom (in the United States) which has a total volume 
of unconfi ned space appropriate to the particular installa-
tion.  Refer to the National Fuel Gas Code ANSI Z223.1/
NFPA54 (current edition), The Uniform Mechanical 
Code - (current edition)
, and local Building Offi cials for 
the options allowed in obtaining an effective bedroom vol-
ume of unconfi ned space.
This model (natural gas and propane) can be installed in 
a bedroom (in Canada) if a thermostat (Model WH-STAT
is installed with the unit. Consult local code authorities.  
Detailed installation instructions for Model WH-STAT are 
included with the kit.
D. High Altitude Installations
U.L. Listed gas appliances are tested and approved without 
requiring changes for elevations from 0 to 2000 feet in the 
U.S.A. and Canada.
When installing this appliance at an elevation above 2000 
feet, it may be necessary to decrease the input rating by 
changing the existing burner orifi ce to a smaller size. Input 
rate should be reduced by 4% for each 1000 feet above 
a 2000 foot elevation in the U.S.A., or 10% for elevations 
between 2000 and 4500 feet in Canada. If the heating 
value of the gas has been reduced, these rules do not 
apply. To identify the proper orifi ce size, check with the 
local gas utility.
If installing this appliance at an elevation above 4500 feet 
(in Canada), check with local authorities.
Listing and Code Approvals 
 
Do NOT use this appliance if any part has been under water. 
Immediately call a qualifi ed service technician to inspect the 
appliance and to replace any part of the control system and 
any gas control which has been under water.
WARNING
Note:  This installation must conform with local codes. In the 
absence of local codes you must comply with the National 
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and 
the CAN/CGA B149 Installation Codes in Canada.
Models
(U.S. or Canada)
Maximum
Input 
BTU/h
Minimum
Input 
BTU/h
Orifi ce 
Size  
(DMS)
 8000TV-OAK
US
0-2000 FT
37,500
26,000
#31
CAN
2000-4500 FT
33,750
23,400
#32
 8000TVLP-OAK-IPI
US
0-2000 FT
37,500
24,000 1.8 mm
CAN
2000-4500 FT
33,750
21,600
#51
 8000TV-OAKIPI
US
0-2000 FT
37,500
26,000
#31
CAN
2000-4500 FT
33,750
23,400