Bosch d9412gv3 User Manual

Page of 76
D9412GV3/D7412GV3 | Operation and Installation Guide | 5.0 
Power Supply 
 
Bosch Security Systems, Inc. | 10/10 | F01U143070-03 
23
 
3.  Connect the black battery lead to Terminal 4, and 
then to the negative (-) side of the battery.  
4.  Connect the red battery lead to Terminal 5, and 
then to the positive (+) side of the battery. 
 
Warning: High current arcs are possible. 
The positive (red) battery lead and 
Terminal 5 can create high current arcs if 
shorted to other terminals or the 
enclosure. Use caution when working 
with the positive lead and Terminal 5. 
Always disconnect the positive (red) lead 
from the battery before removing it from 
Terminal 5. 
 
 
Caution: The battery terminals and wire 
are not power limited. A 6.4 mm (0.250 
in.) space must be maintained between 
the battery terminals, battery wiring, and 
all other wiring. Battery wiring cannot 
share the same conduit, conduit fittings, 
or conduit knock-outs with other wiring.  
 
Figure 7:  Battery Terminals 
1 -  Battery terminals. Terminal 5 is non-power 
limiting. 
Figure 8:  Non-Power-Limited Wiring 
 
1 -  Conduit required for use with external batteries. 
2 -   Battery wires 
3 -   6.4 mm (0.25 in.) minimum. To ensure proper 
spacing, use tie-wraps or similar devices to 
secure wires.   
4 -   Relay output wires 
5 -   Input or Zone wires 
6 -   Standby battery