D9412GV3/D7412GV3 | Operation and Installation Guide | 10.0 Off-Board Relays 
 
Bosch Security Systems, Inc. | 10/10 | F01U143070-03 
50
 
10.0 Off-Board Relays 
10.1 D8129 
OctoRelay 
Use the D8129 OctoRelay to add relay outputs to the 
system in groups of eight. On the D9412GV3, up to 
128 OctoRelay outputs (relay numbers 1 to 128) can 
be added to the system using 16 OctoRelays. 
D7412GV3 allows up to 64 relay outputs. Review 
Section 6.0 Power Outputs on page 26 to ensure that 
enough power is provided for the OctoRelays and 
other powered devices that are connected to the 
system.  
OctoRelays for relay numbers 1 to 64 connect to  
Zonex 1, Terminal 28. OctoRelays for relay numbers 
65 to 128 connect to Zonex 2 (D9412GV3 only), 
Terminal 26 on the D9412GV3. Refer to Figure 24 on 
this page and Figure 25 on page 51. 
Alarm output, auxiliary relay, sensor reset, arming 
status, point status, alarm memory, or remote 
functions can be assigned to the OctoRelay outputs 
individually. Refer to Relay Parameters  in the 
D9412GV3/D7412GV3 Program Entry Guide 
(P/N: F01U170807) for programming details. 
D8129 Restricted for Fire Systems: D8129 relay 
outputs are not supervised and cannot be used in fire 
or combined fire and burglary installations for primary 
indicating devices. 
 
Figure 24:  D8129 Connections to the D9412GV3 
 
1 -  D8129 OctoRelays for relay numbers 1 to 64. 
Connect OctoRelays in parallel. 
 
2 -  D8129 OctoRelays for relay numbers 65 to 
128. Connect OctoRelays in parallel. 
3 -  Power limited