D9412GV3/D7412GV3 | Operation and Installation Guide | 12.0 SDI Devices 
 
Bosch Security Systems, Inc. | 10/10 | F01U143070-03 
60
 
12.4 D9210B 
Wiegand 
Control Interface 
Module 
The Bosch Security Systems, Inc. D9210B Wiegand 
Control Interface Module is a four-wire powered 
device providing connections for an access door point 
and door strike. The D9412GV3 can supervise eight 
Wiegand Control Modules, the D7412GV3 can 
supervise two. Each D9210B supports one door to 
control access. Programming allows each access 
door to be configured independently. 
12.4.1 Access 
Using Wiegand style cards or tokens, the D9210B can 
allow access for up to 996 cards or tokens on the 
D9412GV3, and up to 396 on the D7412GV3. User 
access authority can be configured to restrict access 
to certain doors or to certain periods of time. The 
reading of access cards, in addition to granting 
access, can control whether the system disarms. 
Used with the D9412GV3, the D9210B recognizes 
249 master users by user name, passcode, and 
access authority. The D9210B recognizes 99 master 
users when used with the D7412GV3. Each master 
user supports three sub-users with unique cards or 
tokens having the same access level as the master 
user. 
12.4.2 Switch Settings 
Switches on the D9210B assign a unique address 
(1 to 8) to each module. Table 23 shows the correct 
switch setting for each D9210B address. 
Table 23:  Address Switch Settings for  
Access Control Module 
 
DIP Switch Settings 
Door Module 
Addresses 
1 2 3 
4
1
 
5
2 
6
2
 
ON 
ON 
ON 
 
ON 
ON 
2 OFF 
ON 
ON 
 
ON 
ON 
---------------D7412GV3 Maximum--------------- 
ON OFF ON    ON ON 
OFF 
OFF 
ON 
 
ON 
ON 
5 ON 
ON 
OFF 
 
ON 
ON 
OFF 
ON 
OFF 
 
ON 
ON 
7 ON 
OFF 
OFF 
 
ON 
ON 
OFF 
OFF 
OFF 
 
ON 
ON 
1 
Switch 4, Fail Safe Mode: 
 
ON =  If SDI bus fails, relay energizes. 
OFF = If SDI bus fails, relay de-energizes. 
2 
Switches 5 and 6 must remain in the ON position. 
 
 
 
 
12.5 SDI 
Addresses 88 and 92 
SDI Addresses 88 and 92 are available with the 
D9412GV3 and D7412GV3 Control Panels and are 
used for several different applications. Only one 
device can be assigned to SDI Address 88 at a time. 
Likewise, only one device can be assigned to SDI 
Address 92 at a time. 
12.5.1  D9133DC Direct Connect Programming 
Module 
Use the D9133DC Direct Connect Programming 
Module to handle local programming of the 
D9412GV3 and D7412GV3 Control Panels. In 
addition, the D9133DC allows diagnostic and history 
retrieval.  
 
The D9133DC is not UL Listed, and 
cannot remain connected to the system 
for UL applications. 
UL requires that the D9133DC be used 
for programming only. 
 
 
D9133DC uses SDI 88 only. 
Connecting the D9133DC 
1.  Configure D9133DC for SDI Address 88. To 
program the control panel when the reset pin is in 
the unlocked position, program Enable SDI RPS 
to Yes in the GV2AUX handler. 
2.  Connect D9133DC to Com Port 1 or Com Port 2 
on the PC. The D9133DC has a DB-9 female 
serial connector. A null-modem cable must be 
purchased separately to connect the D9133DC to 
a PC. 
3.  Using 0.8 mm (22 AWG) or 1.2 mm (18 AWG) 
wire, connect the D9133DC SDI terminals (SDI 
PWR, SDI A, SDI B, and SDI COM) to the control 
panel’s SDI terminals (Terminals 29 to 32). 
To send or receive the control panel’s program, place 
the Reset Pin in the Locked or Unlocked position. 
 
 
Locking the Reset Pin when 
programming the control panel improves 
the uploading and downloading times.