3.0 Overview 
3.1 
Configuration and Parts 
Figure 1:  System Configuration 
Control
Panel
On-Board Points
1 to 8
D9131A Module connects
to a parallel printer to print
the event log.
D928 Module allows the control
panel to monitor two phone lines.
Each D8128D OctoPOPIT combines
eight POPIT points in one module.
D8132 Modules (two 12 VDC batteries)
provide additional power for keypads and
other powered devices.
D8129 OctoRelay provides alarm
and auxiliary relay output.
(Other functions available.)
D9210B Modules can be
used for access control.
Use keypads or keyswitches to arm the control panel by
area. The D9412GV3 control panel supports up to 32 areas.
The D7412GV3 control panel supports up to 8 areas. Each
area can have its own account number or areas can be
grouped together with a common account number. Points of
protection are assigned to areas.
D8125, ISW-D8125CW-V2 or D8125MUX
Interface used for point expansion.
DX4020 or ITS-DX4020-G allows
communciation over a Local or Wide
Area Network (LAN/WAN).
 
 
 
Table 2: 
GV3 Series Control Panel Differences 
 
Features 
D9412GV3 
D7412GV3 
D7212GV3 
Access Control 
Yes - 8 doors 
Yes - 2 doors 
No 
Arm/Disarm Passcodes 
249 
99 
99 
Cards/Tokens 
996 
396 
N/A 
Passcode-Protected Custom Functions 
16 
Number of Printers 
Number of Points 
246 
75 
40 
Number of Relays 
128 
64 
24 
Number of Areas 
32 
Number of D1255 Keypads 
16 
16 
Number of D1260 Keypads