Sony 530P User Manual

Page of 208
Chap
te
9
   Set
ting Up th
e Camc
orde
r
151
9-2 Adjusting the Viewfinder
1
Turn the arm of the rotation mechanism assembly of 
the BKW-401 in the direction of the arrow in the 
following illustration. 
Next, using a hexagonal wrench 3 mm across flats, 
remove the bolts (M4 
× 8), to separate the rotation 
mechanism assembly from the viewfinder front-back 
positioning mechanism assembly.
2
Remove the two M3 
× 10 hexagon socket bolts from 
the front-back positioning mechanism assembly, 
together with the washers. Take care not to lose these 
bolts and washers.
3
Using a hexagonal wrench 2.5 mm across flats, detach 
the viewfinder shoe from the camcorder body.
4
Using the two bolts (M3 
× 10) and washers removed in 
step 2, attach the rotation mechanism assembly of the 
BKW-401 to the camcorder.
9-2-6 Detaching the Eyepiece
Removing the eyepiece gives a clearer view of the screen 
from further away. It is also easy to remove dust from the 
viewfinder screen and mirror when the eyepiece is 
detached.
1
Turn the eyepiece locking ring fully counterclockwise, 
to align the red marks on the locking ring and the 
viewfinder barrel.
2
Detach the eyepiece.
Reattaching the eyepiece
1
Align the red marks on the eyepiece locking ring and 
the viewfinder barrel.
2
Align the red mark on the end of the eyepiece end with 
the red marks on the eyepiece locking ring and the 
viewfinder barrel. Then insert the eyepiece into the 
viewfinder barrel.
Hexagon socket bolts 
(M3 
× 10)
Red mark
Locking ring
Line up the red marks.
Red mark