Unibrain 630 User Manual

Page of 73
Unibrain Fire-i 530/630/830 Operation Manual 
Page 29 
 
 
 
 
 
 
3.9.7.  Trigger Mode 3  
 
Not supported at Format 7 Mode 
This is an internal trigger mode. The camera will issue a trigger internally and the cycle time is N times (parameter) 
the  cycle time of  the  fastest frame rate.  The  Integration time of the  incoming light is described  in  the  “Shutter” 
register. A Parameter is required and shall be one or more (N>=1). 
 
 
 
 
3.9.8.  Trigger Mode 4   
This mode is the “multiple shutter preset mode”. The camera starts the integration of the incoming light from the 
first external trigger input falling edge and exposes the incoming light at shutter time. Repeat this sequence for the 
N-th (parameter) external trigger input falling edge and then finish integration. A parameter is required and shall be 
one or more. (N >= 1).