Maintenance
27
70400301
Quarterly Maintenance
Bi-Annually Maintenance
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be 
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Use a vacuum to clean air vents on 
drive motors.
Use a vacuum to clean lint from rear 
limit thermostat cover. 
Check and clean steam coils.
Check flow of combustion and 
ventilation air.
Check belt tension and condition. 
Replace worn or cracked belts.
Check mounting hardware for any 
loose nuts, bolts or screws.
Check gas connections for leakage.
Check for loose electrical connections.
Check steam connections for looseness 
and leakage.
Remove all front panels and vacuum, 
including coin drop mechanisms.
Check cylinder and front panel seals.
Inspect cabinet and inner panels for any 
damage, replace or repair as needed.
Clean burner tubes of any lint buildup.