• Both power supply modules malfunction 
• Both power supply modules are powered down 
• When the AC line fails 
Temperature Gauge 
The 6-Slot Rackmount/Desktop Chassis includes a temperature monitoring gauge with a heat 
sensor on the backplane of the chassis.  Users define a threshold for chassis temperature via 
SNMP.  If the chassis’ temperature rises above the specified level, the SNMP agent sends a 
trap (configured in iView²) to the administrator.  There is also an LED indicator on the SNMP 
Management Module for chassis temperature. 
SNMP Write Lock 
There is an SNMP Write Lock switch located above the SNMP module slot on the front of the 
6-Slot Rackmount/Desktop Chassis.  The SNMP Write Lock switch prevents a new 
management board from re-configuring the 
application module settings (e.g., the status 
of features 
such as LinkLoss, FiberAlert, Force mode, 
etc.) made 
via SNMP on any previous Management 
Modules. 
 
NOTE 
Leave this switch in the NORMAL position during day-to-day operation; the LOCKED 
position should only be used when changing the SNMP management board. 
 
The SNMP Management Module can be removed and replaced as necessary.  Refer to the 
SNMP Management Module manual for complete instructions about configuration and 
operation.  If an SNMP Management Module is installed, refer to the LED panel below for 
indicators of Link, Temperature, Power Supply modules and other functions. 
 
 
 
 
SNMP Management Module LEDs 
The SNMP Management Module features several LEDs.  The LED functions are: