in iView²) to the administrator.  There are also two LED indicators on the SNMP Management 
Module for fan failure. 
The red Alarm Reset Button also functions as a Fan Test button.  To verify fan functionality, 
hold the button down for several seconds, the fans should engage.  The fans will turn off 
when the button is released. 
SNMP Management Modules include two twisted pair ports, one for management and one 
reserved for future use.  The Management Module also features a DB-9 serial port, and 
supports SNMP V1/V2c. 
Installing Management and Application Modules 
Installing Applications Modules 
To install a module: 
1.  Remove the blank bracket (if present) covering the slot where the module will be 
installed.  Black Box recommends installing blank brackets in unused module slots.  
2.  Slide the module into the chassis using the card guides. 
3.  Secure the module to the chassis by tightening the captive screw.  (Refer to the 
documentation shipped with the module for configuration information.) 
4.  When installing modules observe ESD precautions, refer to the Electrostatic Discharge 
Precautions section. 
In order to manage a 6-Slot Rackmount/Desktop Chassis, the SNMP Management Module 
needs to be installed in the appropriate slot of the chassis.    
•  Install the 6-Slot Rackmount/Desktop Chassis into the first slot on the far left of   the 
chassis. 
NOTE 
This slot is ONLY for the Management Module; do not install Application Modules such as 
media conversion and mode conversion modules into this slot.