Mitsubishi Electronics SW0D5C-CNVW-E User Manual

Page of 76
4 - 22                                                                                                                                                       4 - 22
MELSOFT
4   CONVERTING TEXT,CSV FORMAT DATA TO GX Developer FORMAT
DATA
4.3  Handling of conversion errors
This section explains the corrective actions when a conversion error is generated when
data in TEXT, CSV format is import by the GX Developer.
(1)  Conversion error display
3)
1)
2)
     Caution
     • About the error line for an Instruction or I/O (Device)
       error
       If an I/O (Device) error occurs when multiple I/O (Device)
       exist for a single instruction, the line number for the
       Instruction will be displayed as the error line number.
Verify or save the conversion error.
First perform the following operations, then correct
the conversion error.
1)  To save the conversion errors
     Save the conversion error contents to a
     specified file by clicking on the  Save  button.
     Up to 100 occurrences (lines) of errors can be
     saved.
2)  To discard conversion errors
     Click the  OK  button to end the conversion
     processing and then close the GX Converter.
3)  Up to 100 occurrences (lines) of conversion
     errors will be displayed.
     When the number of conversion errors
     exceeds 100 occurrences (lines), the message
     "Convert error counter is over 100. Cancelled
     over 100 errors" will be displayed on line
     number 101.
     See Appendix 2, "Conversion error message
     List" for detailed explanations of error
     messages.
Ends the conversion 
processing and closes 
the GX Converter.
(Continued on the next page)