Acer F900 User Manual

Page of 88
Chapter 4
1
Diagnostics and Troubleshooting
Using DebugSwitcher Function Testing
RUN IN and Discharge Tests
NOTE: 
Wear anti-static gloves.
1.
Insert the battery, battery cover and charger in to the handset 
and power on.
2.
Tap LED and wait for the keypad LED to light. Tap OK to test.
3.
Tap BurnIn Test for Run in testing.
4.
When the screen shows PASS the handset has passed all 
tests,
5.
Check if the handset LED always lights green. If yes, handset 
passed.
6.
Check if the temperatures of the handset, battery and charger 
are OK and not too high. If the temperature is excessively 
high, the handset failed.
7.
If the handset, battery and charger is OK, take the charger 
off.
8.
Unplug the travel charger and go back to the Debugswitcher 
display. Click the DCB to discharge the battery.
9.
After discharge, check if the battery capacity is less than 55% 
and if the screen shows Pass. If so, the handset passed.
10. Check if the handset and battery temperature is excessively 
high. If not, the handset passed.
Chapter 4