Spectralink E340 User Manual

Page of 60
SpectraLink Corporation 
Configuration and Administration—NetLink e340/i640 Wireless Telephone 
 
Mitel Networks 3300 and SX-200 ICP and 5220 IP Phone emulation 
3.3 
Startup Sequence 
The handset goes through an initialization sequence at startup. The line icons 1-9 
display and count down as the handset steps through this sequence. This is usually 
very rapid. If there is any difficulty at any step that prevents initialization from 
continuing, an error message will display and the related icon(s) will stay on. Please 
see the error table at the back of this document for instructions on how to handle 
error messages that occur during initialization. 
Icon 
The icon(s) shown in bold turns off when: 
123456789 
The handset has located and authenticated and associated with at least one AP, and is 
proceeding to bring up higher-layer networking functions. 
12345678 
The handset is either configured for Static IP, or if configured for DHCP the DHCP discovery 
process has started. 
1234567 
If DHCP is configured, a DHCP response was received which contains a good DNS server 
configuration. 
123456 
Note: Only valid on non-SRP protocol. Indicates one of the following:  
Static IP configuration, or 
SVP Server address found in DHCP response, or  
SVP Server address found via DNS lookup. 
12345 
All networking functions are complete (notably, DHCP) and the handset is proceeding with 
establishing the SRP link to the SVP Server. 
1234 
The SRP link is established, all network stack initialization is complete, proceeding with 
application-specific initialization. 
123 
The link between the handset and the PBX is established. 
12 
The handset has registered to the PBX.  
12 
Please Enter PIN 
Requested if PIN had not previously been entered, if PIN has been cleared, or if MAC address 
not entered in the DN con-figuration table on the PBX. 
The PIN may be up to 18 characters. The first few are a secret number defined at the PBX, the 
rest are the extension of this handset. User must enter a valid PIN number and press the 
Send softkey. Alternately, the handset may be configured in the DN configuration table on 
the PBX. 
Note: there is no timeout and the user must reboot if an invalid PIN is entered. 
The handset has received a definition string for each of the 14 programmable buttons. If the 
handset hangs up at this point, there has been an undetected error in the retrieval process 
and the handset will need to be rebooted. 
(no icons) 
 
EXT. XXXXX 
Initialization is complete. The handset is in standby mode ready to receive and place calls. 
PN: 72-1084-02-E.doc 
Page 13