A&D HW-60KV-WP User Manual

Page of 72
HV-WP/HW-WP Series
Page 13
6.1. Display and Symbols
Display and Symbols
Meaning
A
Example. Storing the unit mass of the counting mode.
This is a display of zero point for the counting mode and
uses 20 pieces for the registration.
A
A
A
A
Example. Storing the unit mass of the counting mode.
The sign "-" means "weighing value is not zero".
Sample number is 10 pieces.
A
A
A
A
Example. Percentage mode.
This mode uses the registered 100% mass,  and converts
the weighing value to a percentage. The unit is %
 .
A
A
A
A
Example. Display of the function table.
This function table sets parameters of items.
< switch
Selecting an item.
∧ switch
Selecting the parameter of an item.
 
 ENTER 
 switch
Storing new parameters.
A
A
A
A
A
Example. Preset tare. Entering tare with digital input.
< switch
Selecting a figure.
∧ switch
Selecting a number.
 
 ENTER 
 switch
Storing a new tare.
A
A
A
A
Example. Hold display
The hold display is set using f12 of the function table.
When the value is "nearly-zero" or changes more than
25% +30 digits, the hold is canceled.
A
A
A
A
Over load display.
Remove the mass from the weighing pan.
A
A
A
A
Weighing error.
Check the base unit and weighing pan.
A
A
A
A
Calibration error.
The calibration mass is too light.
Check the base unit and weighing pan.
A
A
A
A
Calibration error.
The calibration mass is too heavy.
Check the base unit and weighing pan.
A
A
A
A
The " nearly-zero " is within ±4 digits from zero point in the unit of kg.