6 Configuration 
Grandstream HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 can be configured 
via Web GUI Interface as well as via Configuration File through TFTP or HTTP. 
 
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 accepts configuration files in a 
proprietary binary format which is produced by the Grandstream configuration tool.  The 
configuration tool creates a device configuration file based on a configuration template and 
the device’s MAC address.  All Grandstream products’ sample configuration templates are 
available on Grandstream’s web site
 A configuration template file contains all 
configuration parameters available for a product, with comments describing allowed 
values of the parameters.  For a detailed parameter list, please refer to the corresponding 
firmware release configuration template 
 
When Grandstream device boots up or reboots, it will issue request for a binary 
configuration file named “cfgxxxxxxxxxxxx”, where “xxxxxxxxxxxx” is the MAC address of 
the device, i.e., “cfg000b820102ab”.  The configuration file name should be in lower cases. 
 
Grandstream offers free Configuration File generator software in both Linux/Unix and 
Windows platform.  Both Configuration File Generators can be downloaded from 
Grandstream official web site at 
  
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 can be configured with a 
configuration file using the Trivial File Transfer Protocol (TFTP) or through its embedded 
web server.  The following examples describe how to set the parameters using a 
configuration file.  This configuration description assumes the HT-286 / HT-386 / HT-486 / 
HT-488 / HT-496 / BT-100 will use the Dynamic Host Configuration Protocol (DHCP) to 
obtain an IP address and other network settings.  The HT-286 / HT-386 / HT-486 / HT-488 
/ HT-496 / BT-100 should be configured to load the configuration file each time it resets or 
re-synchronizes.  For detailed information on automated provisioning, please check the 
HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 User Manual 
Error! Reference 
source not found..
 
The capabilities of the HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 have been 
verified for use with BroadWorks based on the settings described in the following table.  
For more information on the meaning, purpose, and applicability of the individual 
configuration items, see the HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 
configuration template 
 . 
Configuration Files 
Files Provided by Partner 
Level 
Description 
HT-286 / HT-386 / HT-486 / HT-488 / HT-
496 / BT-100 Configuration Template 
Example:  sipp1_config_1.1.0.8.txt 
                 sipp2_config_1.0.3.96.txt 
System and 
Subscriber 
Contains configurable parameters that 
apply to an individual device in a 
deployment. 
cfgMAC 
Example: cfg000b82000000 
System and 
Subscriber 
Binary configuration file generated 
from configuration template and an 