ViewStation EX, ViewStation FX, and VS4000 API Guide    
© Polycom, Inc. 2003
181
pricallbycall <set|get> [{0..31}]
pricallbycall set [{0..31}]
pricallbycall set
pricallbycall get
Description
This command sets the PRI area code. Call-by-call is a number from 
1 to 31, which is optionally sent to an upstream telephone company 
switch, if required. For example, specify a value of 6 for a T1 PRI 
network interface module that is directly connected to an ATT 5ESS 
switch, which is provisioned with Accunet. You must consult with the 
telephone company service provider to determine whether a 
call-by-call value is required for a particular PRI line. For most cases, 
the default value of 0 is correct. Always use the value 0 when 
connected to a PBX. A non-zero value should not be required in 
Europe. Values greater than 31 are reserved for internal use and 
must not be used
set
Sets PRI call-by-call when followed by a value from 
{0..31}. If you want to erase the current setting, omit the 
value.
get
Displays the current setting.
0..31
Range of call-by-call values.
Example
pricallbycall set 1
User Interface Screen Location
System Info>Admin Setup>Video Network>IMUX>PRI Network>
 
PRI Setup>Advanced PRI Setup: Call-by-Call
This screen is only accessible if you have a PRI network interface 
connected to your ViewStation FX or VS4000 system.
pricallbycall