Polycom VIEWSTATION EX User Manual

Page of 224
ViewStation EX, ViewStation FX, and VS4000 API Guide    
© Polycom, Inc. 2003
187
prilinebuildout <set|get><0|-7.5|-15|-22.5>|
 
<0-133|134-266|267-399|400-533|534-665>
prilinebuildout set <0|-7.5|-15|-22.5>
prilinebuildout set <0-133|134-266|267-399|
 
400-533|534-665>
prilinebuildout get
Description
This command sets the PRI line buildout for a T1 interface. If you are 
using an internal CSU, enter the output attenuation in dB. If you are 
using an external CSU, enter the output attenuation in feet.
set
Sets the PRI line buildout. It requires a parameter 
from <0|-7.5|-15|-22.5> or from 
<0-133|134-266|267-399|400-533|534-665>.
get
Displays the current setting.
0|-7.5|-15|-22.5 Available output attenuation values in dB. For 
internal CSUs.
0-133|134-266|267-399|400-533|534-665
Available output attenuation values in feet. For 
external CSUs.
Example
prilinebuildout set -7.5
User Interface Screen Location
System Info>Admin Setup>Video Network>IMUX>PRI Network>
 
PRI Setup: Line Buildout
This screen is only accessible if you have a PRI network interface 
connected to your ViewStation FX or VS4000 system.
prilinebuildout