Sony PVM-9L2 User Manual

Page of 112
Location and Function of Parts and Controls
24
Location and Function of Parts and Controls
Control Panel
POWER ! switch
Press this switch to turn on the monitor. The lamp will 
light up. Press this switch again to turn off the monitor.
VOLUME control
CONTRAST control
PHASE control
Note
When you use a PAL or component signal, phase cannot 
be adjusted.
CHROMA control
BRIGHT (brightness) control
MENU/EXIT button
Press this button to show or hide on-screen menus.
ENTER/SELECT button
Press this button to confirm an item selected on the menu.
i M/+ (move the cursor up/adjust the value) 
button
m/– (move the cursor down/adjust the value) 
button
Press these buttons to move the cursor or adjust an item 
selected on the menu.
EXT SYNC (external sync) button and lamp
Press this button to operate the monitor synchronized 
with an external sync signal input through the EXT 
SYNC connector.
16:9 button and lamp
Press this button to monitor a signal whose aspect ratio 
is 16:9.
UNDERSCAN button and lamp
Press this button for underscanning.
The display size is reduced by approximately 5% so that 
the four corners of the picture are visible.
BLUE ONLY/RESET button and lamp
• As the BLUE ONLY button, press this button to 
eliminate the red and green component of input 
signals. Only the blue component of an input signal is 
displayed on the screen. This facilitates adjustments of 
chroma and phase, and observation of VCR noise. 
(Phase adjustment is effective only for NTSC signals.)
• As the RESET button, you can reset the menu item 
setting to the previous one by pressing this button 
while the new item is being selected and adjusted.
DEGAUSS button and lamp
Press this button only once. The screen will be 
demagnetized. Wait for 10 minutes or more before using 
this button again.
Note
The DEGAUSS button is disabled when the screen 
menu is being displayed.
To manually degauss the monitor, first, exit the screen 
menu by pressing the MENU/EXIT button.
LINE A button and lamp
Press this button to monitor the signal input through the 
LINE A connectors.
LINE B button and lamp
Press this button to monitor the signal input through the 
LINE B connectors.
w;
POWER
VOLUME
CONTRAST
PHASE
CHROMA
BRIGHT
MENU
ENTER
16 : 9
+
MIN MAX PUR GRN MIN MAX MIN MAX
E X I T
SELECT
RESET
OPTION
B
UNDER
SCAN
BLUE
ONLY
DEGAUSS
1
2
3
4
5
6
7
8
9
qa
EXT
SYNC
q;
qs
qd
qf
ql
qk
qj
qh
qg
RGB/
COMPONENT
OPTION
A
LINE
A
LINE
B