Honeywell W8735B User Manual

Page of 12
TELEPHONE ACCESS MODULE
9
69-1352
a
The W8735B prompts for setting the dial-out telephone number type as data or voice; choose voice because data is 
reserved for future applications.
5
Pass Code.
This setting provides secure access for the 
homeowner’s comfort settings. (Installer: Have the 
homeowner enter this setting either at the time of 
installation or at their convenience.) 
Any combination of four digits.
(Default pass code is 1234.)
6
Zone ID Names (if zoning installed).
When more than one thermostat is installed in a 
system, a name can be assigned to each zone 
thermostat.
Choose from a list of 26 zone names. (See 
Table 4.)
7
Filter Change Setting (enable/disable).
The W8735B can initiate a dial-out alert when the 
HVAC equipment filter needs replacing. (If not 
desired, set the value to disable.)
Enable or disable. (Enable is the default.)
8
Dial-out Alert Setting (enable/disable).
The W8735B can dial out on an alert condition. 
See Table 5. (If not desired, set the value to 
disable.)
Enable or disable. (Enable is the default.)
9
Dial-out Telephone Number Settings.
W8735B can store up to three telephone numbers 
to dial out
a
:
Telephone number setting one: The 
homeowner selects a number where they can 
be contacted when away from home (such as 
office, second home, or cellular phone 
number).
Telephone number setting two: An alternate 
contact when the homeowner cannot be 
reached (such as relative, friend or neighbor).
Telephone number setting three (HVAC 
contractor is providing monitoring service at 
homeowner’s request): The HVAC contractor 
phone number.
IMPORTANT
If these numbers are not programmed, a 
dial-out is not initiated on alert. Tele-
phone setting numbers one and two are 
for the homeowner. 
Up to three telephone numbers can be 
programmed. (Each telephone number 
can be any combination of 25 digits.)
10
Power Outage Setting,
The W8735B can monitor if the power is 
interrupted (when a 9 Vdc alkaline battery is 
installed). When power is interrupted continuously 
for longer or equal to the power outage setting, the 
W8735B initiates a dial-out alert.
1, 2, 3 or 4 hours. (Factory default is 1 
hour.)
11
Software Version Number.
Identifies version of software in Telephone Access 
Module.
None
Table 3. Configuration Menu. (Continued)
Configuration No.
Description
Settings