Manageability
• Remote supervision—the Evolution comes with a free five-
node version of Enterprise Power Manager for network-based
supervision and asset management
• Includes network-based modules for power management
of servers (Windows, Linux, MacOS) or small blade servers
(VMware ESX, Microsoft Hyper-V)
• NetWatch 5.0 software enables automatic shutdown of UPS-
protected devices
Eaton customer service and support
• Two-year warranty, including batteries
• Standard exchange of product in case of failure,
• Standard exchange of product in case of failure,
including batteries
Associated services:
• Warranty+: Three- or five-year extended warranty
• Battery replacement program
• UPSgrade
• Battery replacement program
• UPSgrade
™
program for substitution of an old UPS
(vendor neutral)
Communications software and connectivity
• Power management suite (included) comes with network-based
shutdown software (Windows, Linux, MacOS, VMware ESX,
Microsoft Hyper-V) and local or remote supervision up to five
nodes
• Network Management Card (NMC) connects the UPS to an
Ethernet 10/100 network, raising SNMP or XML alarms and
supervising the UPS using a simple browser interface
• NMC environment sensor monitors the temperature, humidity
and two relay contacts via SNMP or HTML
• Enterprise Power Manager supervisor provides comprehensive
management of multiple UPSs and PDUs using a Windows PC
(vendor neutral)
• NMS integration kits include HP OpenView, IBM Tivoli Netview,
CA Unicenter, etc.
• Management card contacts/serial provide UPS status outputs
via relay contacts, emergency stop and a second serial port
• NMC ModBus/JBus card combines SNMP, HTML and ModBus/
JBus supervision
• UPS control remote display monitors UPS status up to 82 feet
from the unit
Eaton NetWatch Client 5.0 has tested compatible
with Cisco Unified Communications Manager 4.3.
Go to www.eaton.com/PQ/cisco for disclaimer.
with Cisco Unified Communications Manager 4.3.
Go to www.eaton.com/PQ/cisco for disclaimer.
Technical specifications
1
ElEctrical charactEristics
Topology
Line-interactive high frequency
(buck and boost)
Input voltage range (without batteries) 89–151V (adjustable to 80V-153V)
Input frequency range
Input frequency range
(without batteries)
56.5–70 Hz (60 Hz system)
2
,
47–70 Hz (50 Hz system)
Output voltage
120V (+6/-10%)
3
Output frequency
50/60 HZ (± 0.1%)
connEctions
Remotely controlled individual
receptacles
650–1550 VA: (2) 5-15R
1750–3000 VA: (2) 5-20R
intErfacEs
Communication ports
(1) USB port, (1) RS232 serial port and
relay contact
4
, (1) mini terminal block
for remote ON/OFF (ROO) and remote
power off (RPO)
Communications card slots
(1) slot for NMC Mini-Slot 2006
card, NMC ModBus/JBus or MC
Contacts/Serial
opErating conditions, standards and approvals
Operating temperature
650–1150 VA: 32°–95°F
1250–3000 VA: 32°–104°F
Noise level
650–1550 VA: ≤40 dBA
1250–2000 VA: ≤45 dBA
2500–3000 VA: ≤50 dBA
Performance/Safety/EMC
IEC/EN 62040-1-1 (Safety), IEC/EN
62040-2 EN 50091-2 class A (EMC),
IEC/EN 62040-3 (Performance),
IEC/EN 61000-4-2, 61000-4-3, 61000-4-4;
61000-4-5, 61000-4-6, 61000-4-8 (EMI)
Approvals
UL, cUL, CE, CB report
1. Due to continuing product improvement programs, specifications are subject to change without notice
2. Up to 40 Hz in low-sensitivity mode (programmable using Personal Solution-Pac software)
3. Adjustable to 100 (10% derating of output)/120/127V; default setting 120V +10/-15%
4. USB and RS232 ports cannot be used simultaneously
Network Managment
Card and Enterprise Power
Manager Supervision
Card and Enterprise Power
Manager Supervision
FlexPDU and HotSwap MBP can be
mounted in many different positions
mounted in many different positions
Eaton corporation Eaton Evolution UPS