Model G0466/G0469 Air Compressors
-
18
-
SECTION 6: SERVICE
This section is provided for your convenience—it is not a substitute for the Grizzly Service 
Department. If you need help troubleshooting, replacing parts, or you are unsure of how 
to perform the procedures in this section, then feel free to call our Technical Support at 
(570) 546-9663.
Symptom
Possible Cause
Possible Solution
Motor will not start. 
1.  Tank already pressurized.
2.  Thermal overload switch 
has tripped.
3.  Low voltage.
4.  Short circuit in motor or 
cord, or loose connec-
tions.
5.  Incorrect fuses or circuit 
breakers in power line.
6.  Pressure switch is bad.
1. Motor will not start if tank 
is fully pressurized.
2. Wait for motor to cool.
3. Check power line for 
proper voltage.
4. Inspect all connections on 
motor for loose or shorted 
terminals or worn insula-
tion.
5. Install correct fuses or cir-
cuit breakers.
6. Replace the pressure 
switch.
Motor fails to develop 
full power (output of 
motor decreases rapidly 
with decrease in volt-
age at motor terminals).
1.  Power line overloaded 
with lights, appliances, 
and other motors.
2.  Undersized wires or cir-
cuits too long.
1.  Reduce load on power 
line.
2.  Increase wire sizes or 
reduce length of the cir-
cuit.
Motor overheats and 
thermal overload turns 
motor 
OFF.
1.  Cooling fins dirty.
2.  Air filter clogged.
3.  Compressor is running 
too long without a break.
4.  Air circulation through the 
motor restricted.
1. Clean cylinder fins and 
motor area.
2. Inspect and clean air filter.
3. Do not use air tools with 
CFM needs that exceed 
the compressor CFM rat-
ing.
4.  Clean out motor to pro-
vide normal air circula-
tion.
Troubleshooting