sEctioN 1.4
PrEParatioN BEforE usE
in  the  selector  knob  and  pull  out  to  overcome  spring 
pressure and then twist clockwise 90 degrees and allow 
the selector to return in once aligned with the LP (Liquid 
Propane) position.
6.  Save this tool with the Owner's Manual.
7.  Install the battery, door and close the roof.
8.  Reverse the procedure to convert back to natural gas.
Figure 1. Demand Regulator
10, 12, 14, 16, 17 AND 20 kW, V-TWIN ENGINES:
To  reconfigure  the  fuel  system  from  NG  to  LP,  follow 
these steps:
note: the primary regulator for the propane sup-
ply  is  not  included  with  the  generator.  a  fuel 
pressure of 10 to 12 inches of water column (0.36 
to 0.43 psi) to the fuel inlet of the generator muSt 
Be Supplied.
FUEL SELECTION 
LEVER -
“IN” POSITION FOR 
NATURAL GAS
Figure 2. 10 kW, GT-530 (Inlet Hose Slid Back)
FUEL SELECTION 
LEVER -
“OUT” POSITION FOR 
LIQUID PROPANE 
(VAPOR) FUEL
Figure 3. 10 kW, GT-530 (Inlet Hose Slid Back)
1.  Open the roof.
2. 
for 10 kW units:
 Loosen clamp and slide back the 
air inlet hose.
•  Slide  fuel  selector  on  carburetor  out  towards  the
back of the enclosure (Figures 2 and 3).
•  Return the inlet hose and tighten clamp securely.
  for 12, 14, 16, 17 and 20 kW units: remove the air 
cleaner cover.
•  Slide the selector lever out towards the back of the
enclosure (Figures 4 and 5).
•  Return  the  air  cleaner  cover  and  tighten  the  two
thumb screws.
3.  Close the roof.
4.  Reverse the procedure to convert back to natural gas.
FUEL SELECTION 
LEVER -
“IN” POSITION FOR 
NATURAL GAS
Figure 4. 12/14/16/17/20 kW, GT-990/GT-999 
(Airbox Cover Removed)
Part 1
Page 17