TANDBERG 6000MXP User Manual

Page of 296
Administrator Settings 
171 
 
4.5.2 
Outputs  
 
 
Audio out 1 - 3  
 
Audio out 1 is intended for connection to TANDBERG Digital Natural Audio Module, televisions or 
audio amplifiers. 
Audio out 2 is intended for connection to audio recording equipment or to a telephone add-on 
hybrid. The signal is a mix of audio from both the far end and local end (not from Audio in 5). 
Audio out 3 is intended for connection to a VCR or other recording equipment. The signal is a mix 
of audio from far end and local end (not from Audio in 6). 
 
Note that audio out 2 or audio out 3 never should be connected to a loudspeaker placed in the 
same room as the microphones connected to the system. This will cause 
howling
 and possible 
damage to the speaker system. If an output is Off, no audio will be sent to that output. 
 
Out 1 Mode  
 
If Out 1 Mode is set to Auto, the system will select analog or digital (SPDIF) mode dependent on 
the detected Audio Module. If a TANDBERG Digital NAM is detected, SPDIF mode will be 
selected, otherwise analog mode will be selected.  
Setting the Out 1 Mode to either Analog or SPDIF will override the auto-detected mode. 
 
 See 
 for more information. 
 
Audio Module 
 
Select Audio Module according to the type of Audio Module installed if this is not automatically 
detected. The Audio Module setting is only available if the audio module of the system is 
unidentified. 
 
Level Settings  
 
Adjust the audio output levels according to the parameters of the external audio equipment 
connected. These levels should only be adjusted when installing new audio equipment. The 
default settings are correct for the TANDBERG Digital Natural Audio module and for most 
consumer electronics devices (televisions, VCRs, etc.). The volume keys on the remote control 
adjust the level of output 1 (the speaker output). The volume control has no effect on other 
outputs.  
 
Please see 
Interfaces
 for details on the audio connectors.