TANDBERG 6000MXP User Manual

Page of 296
Administrator Settings 
217 
 
4.8.4 
Data Port 
 
 
The system provides up to two standard RS232 serial ports to allow a computer to be connected 
for data transfer and control purposes. Note that when connecting to a PC the connecting cable 
must be a straight through RS232 cable. 
 
Baud Rate, Parity, Databits and Stopbits 
 
If you wish to connect a PC to Data port 1, you must ensure that the PC and the system are 
identically configured. The available settings are: 
 
 
Baud 
Rate  
Parity  
Databits  
Stopbits 
 
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 
None, Odd, Even
 
 
7, 8
 
 
1, 2 
 
 
The control interface provided by the data port supports a subset of the Hayes command set as 
well as a comprehensive set of system specific commands. It maintains communication with the 
data port
s command interpreter at all times. All features available from the hand-held remote 
control can be accessed through the data port. 
 
 
 
Data Port 2 
 
Data port 2 is dedicated to the main camera and will not be available in standard configuration. 
The Data Port 2 menu contains the same items as the Data Port 1 menu; Baud rate, Parity, 
Databits, Stopbits except for the Mode, which has VISCA and Auto selections.Mode. 
 
The system will automatically detect WAVE cameras. If you are using a camera supporting the 
VISCA protocol, select Mode: VISCA.  
If Mode is Auto and no camera is connected to the Data port 2, the Baudrate, Parity, Databits and 
Stopbits settings will be enabled.