5.1.4
Data port
The data port(s) are implemented as Data Communications Equipment (DCE). The connector
used are female 9-pin D-subs.
The TANDBERG main camera is normally connected to data port 2 and pin number 4 provides
12V DC / 1 Amps to the main camera. Otherwise the pin-outs for both data ports are the same.
used are female 9-pin D-subs.
The TANDBERG main camera is normally connected to data port 2 and pin number 4 provides
12V DC / 1 Amps to the main camera. Otherwise the pin-outs for both data ports are the same.
Signal name
Direction
Pin
number
number
Carrier detect, CD
From
DCE
DCE
1
Receive data,
RXD
RXD
From
DCE
DCE
2
Transmit data,
TXD
TXD
To DCE
3
Data terminal
ready, DTR
ready, DTR
From
DCE
DCE
4
Signal ground,
GND
GND
5
Data set ready,
DSR
DSR
From
DCE
DCE
6
Ready to send,
RTS
RTS
To DCE
7
Clear to send,
CTS
CTS
From
DCE
DCE
8
Ring indicator, RI
From
DCE
DCE
9