258 
 
6.4 Appendix 4 
 
 
Guidelines for setting up videoconferencing rooms  
 
The following are a set of guidelines to consider when either building a videoconferencing room, 
or using an existing room for videoconferencing. 
 
 
Lighting: 
 
Low Contrast desired for light 
intensity. No dark spots. 
 
Intensity @ table 800 - 1400 Lux as 
measured with an Incident light 
meter. 
 
Block sunlight from entering room.  
                                
Seating Area (Table): 
 
Should allow all participants to see 
Monitors.              
 
Should allow camera to 
see
 all 
participants.             
 
Non-shiny non-patterned preferably 
light grey surface (if table used). 
 
Walls: 
 
Color: Generally high contrast color 
desired. Light blue is commonly 
used. 
 
Acoustically reflective surfaces (such 
as glass or concrete) should be 
covered with curtains or sound 
treatment. 
 
 
Audio: 
 
Noise Floor preferred less than 
44dBC. 
 
Reverb Time  0,3 to 0,5 sec. 
  
Ventilation: 
 
Keep in mind Noise Floor. 
 
 
Velocity = Noise. Therefore keep 
velocity of air low. 
 
Room: 
 
Should be located away from noise. 
 
Should not have windows. 
 
Doors should be located off camera.  
 
 
 
 
 
 
 
How to prepare a typical room for videoconferencing: 
 
The diagram below shows a typical room designed to obtain the best results when using the 
system.