Vidikron VL-40 User Manual

Page of 76
Vidikron VL-40 and VL-46 Owner’s Operating Manual
51 
PRE
L
IMINAR
Y
6.1 
RS-232 Connection and 
Port Configuration
To interface the DView with a home theater automation/control system or a PC running 
terminal emulation software, connect it to your control system or PC as shown in Figure 3-11. 
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit 
and no flow control. Set the baud rate to match that of the DView RS-232 port; the default 
baud rate is 115200. 
6.2 
Serial Command Syntax
• Commands are in ASCII format and are not case-sensitive. 
• A carriage return is not required after a command. 
• When you send a valid command, the DView executes it and acknowledges it with a 
right-bracket character (]) followed by the four-digit numeric code you sent; for example, 
]0002
• When you send an invalid command (one followed by values outside the valid range for 
that command), the DView ignores it and returns >MAX or <MIN instead of the four-digit 
code.
• When you send an unrecognized/misspelled command, the DView ignores it and returns 
-N/A
 instead of the four-digit code.
Table 6-1 lists the RS-232 command set. 
6
Serial Communications
Table 6-1. Serial Commands 
Command
Description
[
S3A
0###
Set audio volume to ### ( = 000-100)
Example:   
[S3A0075
 sets volume to 75
[
+3A
Audio volume up
[
-3A
Audio volume down
[
S3E
000#
Audio mute (speakers/headphones)
 
0 = not muted, 1 = muted
Example:   
[S3E0001
 mutes the audio output
[
S4A
000#
Main input selection
 
0 = TV
 
1 = Input1
 
2 = Input2
 
3 = Input3
 
4 = Input4
 
6 = RGB
 
8 = HDMI1
 
9 = HDMI2
Example:   
[S4A0006
 selects RGB
[
+4A
Select “next” Main AV input