Vidikron VL-37 User Manual

Page of 66
Vidikron VL-37 Owner’s Operating Manual
47 
6.1 
RS-232 Connection and 
Port Configuration
To interface the DView with a home theater automation/control system or a PC running 
terminal emulation software, connect it to your control system or PC as shown in Figure 3-7
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit 
and no flow control. Set the baud rate to match that of the DView RS-232 port; the default 
baud rate is 115200. 
6.2 
Serial Command Syntax
Table 6-1 lists the RS-232 command set. All commands are in ASCII format. A carriage return 
is not required after a command. 
When you send a valid command, the DView executes it and acknowledges it with a 
right-bracket character (
]
) followed by the four-digit numeric code you sent; for example, 
]0002
. When you send an invalid command, the DView ignores it and returns 
-N/A
 instead 
of the four-digit code.
6
Serial Communications
Table 6-1. Serial Commands 
Command
Description
[
+
S3A
+
000#
Set audio volume to ### (=000-100)
Example:   [ S3A000075 sets volume to 75
[
+
+3A
Audio volume up
[
+
- 3A
Audio volume down
[
+
S4A
+
000#
Main input selection
 
1=Input1
 
2=Input2
 
3=Input3
 
4=Input4
 
5=DVI
 
6=RGB
Example:   [ S4A0006 selects RGB
[
+
S4E
+
000#
Aspect ratio selection
 
0=Standard (4x3)
 
1=IntelliWide
 
2=Letterbox
 
3=Anamorphic
Example:   [ S4E0002 selects Letterbox
[
+
S4F
+
0101
Select Composite Video for Input1
+
0102
Select S-Video for Input1
+
0201
Select Composite Video for Input2
+
0202
Select S-Video for Input2
+
0301
Select Composite Video for Input3
+
0303
Select Component Video for Input3