Bosch UML-262-90 User Manual

Page of 54
34
en | Installing the Monitor
Full HD LCD Monitors
F.01U.172.600 | 1.0 | 2010.10
User’s Manual
Bosch Security Systems, Inc.
2.
Configure the following settings for the Dinion camera:
VMD: OSD
Area:  1
Active: On
3.
Connect one flying lead to relay output three (3), on the 
back of the Dinion camera, and connect the other to relay 
output four (4).
4.
Connect the other end of the Trigger cable to the Trigger 
Input connector on the bottom panel of the monitor.
5.
Plug the monitor into a power socket; then press the 
Power button.
6.
On the monitor, access the Trigger menu:
a.
Press the Menu button.
b.
Press the Down Arrow button to access the Setup 
menu.
c.
Press the Right Arrow button to enter the Setup 
menu.
d.
Press the Down Arrow button until Trigger is 
highlighted; then press the Right Arrow button.
7.
Make the necessary changes to the Trigger menu so that 
the settings match the following:
8.
Press the Menu button three (3) times to exit the menu 
and to return to the video display.
Trigger Enable
On
Trigger Input
AV1
Buzzer
On
Trigger Time
10
Trigger Option
High
Move
Enter
Enter
Exit