PIN Number Functions
PIN number  Function
01 
Self Test Mode
03  
Power-save Mode
04  
Exit Power-save Mode
05 01 Call 
 Enable MUGAPLM Learn Mode
06 (1-3) 
 MUGAPLM Volume Control
07 (1-3) 
 MUGAPLM Microphone Sensitivity
7 ### PIN 
Removing PIN Numbers
08 (1-3) 
MUGAPLM Brightness Control
8 (1-4)  
Activating a Remote Control 
Remote (1-4)  Transmitter
09 ### PIN 
Change the Master PIN Number
9 PIN 
Add PIN Numbers
9 PIN (1-4) 
 Add PIN Numbers with GCU 
restrict
51 PIN 
Add Temporary PIN Number
51 PIN (1-4) 
 Add Temporary PIN Number with 
GCU restrict
52 Vacation 
Mode
53 
Exit Vacation Mode
54 Party 
Mode
55 (1-3) 
Alternate Channel Set
56  
Place MUGAPLM in Multi-GAP 
Passive Mode
57  
Place MUGAPLM back to Active 
Mode
58  
Default GCU #3 to the Passive 
MUGAPLM
59  
Default GCU #4 to the Passive 
MUGAPLM
The Passive MUGAPLM defaults to activating GCU #2 
when it is activated by a PIN Number entered on that 
keypad, a near-by Remote Control Transmitter, or if the 
Call button is pressed.
To have the Passive MUGAPLM activate GCU #3:
Enter Master PIN Number on Passive MUGAPLM:
?
?
?
?
5
8
To have the Passive MUGAPLM activate GCU #4:
Enter Master PIN Number on Passive MUGAPLM:
?
?
?
?
5
9
Multi-GAP Default GCU Setting
“BEEP”
“BEEP”
The AA batteries (not provided) in the GCU will last 
up to a year and a half depending on use (Lithium 
batteries recommended for colder environments.) If 
batteries are low, the intercom will beep three times 
after it is activated.
The C batteries (not provided) in the MUGAPLM will 
last up to a year and a half with all functions enabled. 
Not activating remote control transmitters and 
enabling the Power-save Mode can extend battery life 
up to five years.
NOTE: To prevent damage to the circuit DO NOT use 
C size Lithium batteries. If Lithium batteries are 
needed, switch the C battery pack with the provided 
AA battery pack.
Battery
To open a gate enter any valid PIN Number on 
MUGAPLM.
For multiple GCU’s, enter the PIN Number followed 
by the GCU Identity (1-4). 
For a Remote Control Transmitter, hold down the 
corresponding numbered button for 5 seconds (within 
75' of MUGAPLM).
On intercom, press the Remote button while talking to 
a visitor. At other times, hold the intercom’s Remote 
button for 10 seconds, to activate the Primary GCU.
NOTE: When using a MUOTIU or MUOTIU-EX press 
“0” to answer a call.
On a OTIU or MUOTIU, dial “*9” on on the telephone, 
while talking to a visitor.
Open Gate
To make a call dial the directory code then press the 
Call button.
To answer a call press “0” on the phone connected to 
the OTIU or MUOTIU. 
To Answer or Make Call