Panasonic VL-SW250BX User Manual

Page of 56
Help
49
N
 Sub monitor station/Battery
Problem
Cause & Solution
Page
 fl ashes and 2 short beeps 
sound.
L
The battery level is low. Charge the battery immediately.
16
Even if you place the sub monitor 
station on the charger, the 
CHARGE indicator does not light 
up.
L
The AC adaptor is disconnected from the power outlet or 
the charger. Plug the AC adaptor into the power outlet or the 
charger fi rmly.
L
The sub monitor station is not placed on the charger correctly. 
Replace it securely. (A short beep sounds and the CHARGE 
indictor lights in solid red.)
L
The charge contacts are dirty. Clean them with a soft, dry cloth.
L
The battery is new or discharged. Place the sub monitor station 
on the charger and wait for a few minutes.
16
16
52
16
The CHARGE indicator does not 
go off after the battery has been 
charged for about 7 hours.
L
When the power of the main monitor station is turned off or 
“OUT OF RANGE” is displayed on the sub monitor station, the 
charging time will become longer. Make sure the power of the 
main monitor station is turned on, and charge the sub monitor 
station in a location near the main monitor station where “OUT 
OF RANGE” disappears.
16
Even if the sub monitor station 
has been charged,   fl ashes 
after using it a few times.
L
The battery is at the end of its life. Replace the battery with a 
new one.
52
The sub monitor station, the AC 
adaptor, or the charger is warm.
L
This is normal. (It may feel a little warmer in summer than in 
winter.) If it feels very hot, disconnect the AC adapter from the 
power outlet and contact our service personnel.
N
 Others
Problem
Cause & Solution
Page
The main monitor station, the 
sub monitor station, and the 
door station do not work during a 
power failure.
L
 The unit does not work during a power failure. The date and 
time may be reset to the default setting after a power failure. In 
this case, set the date and time using the main monitor station 
again.
17
L
 “DEMO MODE” is displayed.
L
 You cannot answer the call or 
make an intercom call.
L
 Demo mode is activated. Change the setting to “OFF”.
39
L
 The unit does not work with 
correct operations.
L
 The unit does not work properly.
L
Perform the following operation (Reset).
 Main monitor station:
Press the RESET switch on the bottom of the main monitor 
station with a pointed object. (Recorded images and the 
program settings are not affected.)
Sub monitor station: 
Remove the battery and insert it again.
– Program settings are not affected. 
–    is displayed. However, the actual battery level is 
maintained.
10