Alarm Input and Output Details 
You can refer to the following sheet and 
  for alarm input  and 
output information. 
Figure  3-1  Alarm Input and Output  of  HD-DVR-1004,  HD-DVR-1008 
(Left) and HD-DVR-1016 (Right) 
      
 
Parameter 
Grounding Alarm   
 
Ground line 
Alarm Input 
HD-DVR-1004:  1, 2,  3,  4 become valid in low voltage;  5, 6, 7, 8 
are not effective. 
HD-DVR-1008: 1-8 become valid in low voltage. 
HD-DVR-1016: 1-16 become valid in low voltage. 
Relay Output NO C 
1-NO C, 2-NO C, 3-NO C Three Normal Open activation outputs.
 
RS-485 A/B 
RS-485 communication port. They are used to control devices 
such as PTZ. Please parallel connect 120
Ω between A/B cables if 
there are too many PTZ decoders. 
Alarm Input Port  
4-ch (HD-DVR-1004)/8-ch (HD-DVR-1008)/16-ch (HD-DVR-1016) 
grounding alarm inputs. (Normal open or Normal close type) 
Please  parallel  connect  COM  end  and  GND end  of the alarm detector 
(Provide external power to the alarm detector). 
Please parallel connect the ground of the DVR and the ground of the alarm 
detector. 
Please connect the NC port of the alarm sensor to the DVR alarm input 
(ALARM)