15 
 
 
 
CTRL IN
GND
    
 
 
 
  
CTRL IN
GND
 
 
 
 
Idle state   
 
 
 
 
Playback   
 
 
2. Record: 
The input switches to Record (or Record Standby) as long the contact is closed. 
 
 
 
CTRL IN
GND
    
 
 
 
  
CTRL IN
GND
 
 
 
 
Idle state   
 
 
 
 
Record / Record Standby
 
 
3. Armed / Disarmed: If the contact is closed, the DVR will switch off alarm (alarm contact and motion 
alarm) operation. System alarm events are always active. 
 
 
 
CTRL IN
GND
    
 
 
 
  
CTRL IN
GND
 
 
 
 
DVR armed  
 
 
 
 
DVR disarmed
 
 
 
2.3.3
 
Alarm Output Relay 
The relay outputs provide either Normally Open or Normally Closed dry contacts. 
 
 
Output relay in idle state 
 
 
2.4
 
RS-485 keyboard / PTZ Installation 
All  functions  can  be  remote-controlled  by  the  EKB-500  universal  keyboard.  Using  the  EEPbus  protocol, 
digital  video  recorders,  keyboards  and  speed  domes  can  be  installed  on  one  single  RS-485  bus.  One 
system can comprise up to 8 keyboards.