GE Digital Video Multiplexer Recorder User Manual

Page of 75
0150-0229D 
12 
Kalatel DVMRe StoreSafe 
External Alarm Acknowledge Input 
External Device:  Normally Open 
Zero potential relay contact. 
Connect a switch or similar device to ground this pin in order 
to acknowledge an alarm condition, and silence associated 
buzzers and relays.  Connect from pin 23 to either pin 18, 19, 
or 20 (ground pins). 
 
 
 
All specifications subject to change without notice.  GE-Interlogix believes all specifications 
to be correct at time of printing, but no liability is assumed for omissions or errors. 
 
RS485 Connector (StoreSafe Advanced Models Only) 
Wire Type:  #24 AWG, twisted pair with shield                  
(2-wire) 
Connector Type:  RJ-45 
Max. Cable Length: 3200 feet / 1000 meters 
Shields are grounded at one end, preferably at the 
StoreSafe end. 
See section 3.16 for information about configuring 
the RS485 network address settings in the menu 
system. 
 
RJ-45 Pin Configuration For RS485 Port 
Pin 
Use 
 
Pin 
Use 
 
Ground (Shield) 
 
Not Connected 
 
Not Connected 
 
Network -VE 
 
Network +VE 
 
Ground (Shield) 
 
Not Connected 
 
Not Connected 
 
 
 
 
 
 
 
8
2 3 4 5 6 7
1
 
RJ-45 socket on 
back panel. 
 
Ethernet Port 
Wire Type:  Cat 5 
Connector Type:  RJ-45 
Max. Cable Length: 100 meters / 328 ft. 
Min. Cable Length:  6 feet / 1.8 meters 
Hub Wiring Configuration:  Straight Through 
PC Wiring Configuration:  Cross Over 
The cable connection configuration depends on your 
network configuration: 
• 
For a StoreSafe that connects directly to a Hub 
or Switch, use a straight through connection. 
• 
For a StoreSafe that connects directly to a PC, 
use a cross over connection. 
Consult with your MIS personnel for the specific type 
of configuration.  See section 3.16 for information 
about configuring the ethernet settings in the menu 
system. 
 
 
 