GE BusSecure User Manual

Page of 37
DVR Installation and Wiring 
BusSecure User Manual 
 
20 
0150-0263A / May 2003 
 
3.2.2.2  P
ANIC 
B
UTTON 
C
ONNECTIONS
 
The Panic Button’s N/C wire and common wire connect to one of the pairs of input terminals as shown in 
Figure 27. 
Note: The Panic Button also has wires that are used for status outputs. See section 3.2.4. 
 
 
 
 
 
 
 
3.2.3  S
TATUS 
O
UTPUT 
C
ONNECTIONS
 
The BusSecure system provides two status outputs on the P2 terminal block for optional use. The most 
common uses for these outputs are as interfaces to a vehicle relay system or lights. To interface with a 
vehicle relay system, contact the vehicle manufacturer. 
To connect the status lights on the Panic Button to the status outputs, see Figure 28 and perform the 
following: 
1)  Connect the normal wire (green) to terminal 13. 
2)  Connect the check wire (red) to terminal 15. 
3)  Connect the positive wire (gray) to terminal 18.  
4)  If you are installing a Panic Button with a key reset, connect the negative wire (white) to  
terminal 17. 
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
 N
or
m
al
C
he
ck
G
N
D
P
os
iti
ve
 
 
 
Figure 27. Panic Button input connections 
Figure 28. Panic Button output connections