(2) Wires for cables
When fabricating a cable, use the wire models given in the following table or equivalent.
Table 12.3 Wires for option cables
Characteristics of one core
Type
Model
Length
[m(ft)]
Core size
[mm
2
]
Number
of Cores
Structure
[Wires/mm]
Conductor
resistance[ /mm]
Insulation coating
ODd[mm] (Note 1)
(Note 3)
Finishing
OD [mm]
Wire model
2 to 10
(6.56 to 32.8)
0.08
12
(6 pairs)
7/0.127
222
0.38
5.6
UL20276 AWG#28
6pair (BLACK)
MR-JCCBL   M-L
20 30
(65.6 98.4)
0.3
12
(6 pairs)
12/0.18
62
1.2
8.2
UL20276 AWG#22
6pair (BLACK)
2 5
(6.56 16.4)
0.2
12
(6 pairs)
40/0.08
105
0.88
7.2
(Note 2)
A14B2343 6P
MR-JCCBL   M-H
10 to 50
(32.8 to 164)
0.2
14
(7 pairs)
40/0.08
105
0.88
8.0
(Note 2)
A14B0238 7P
2 5
(6.56 16.4)
0.08
8
(4 pairs)
7/0.127
222
0.38
4.7
UL20276 AWG#28
4pair (BLACK)
MR-JHSCBL   M-L
10 to 30
(32.8 to 98.4)
0.3
12
(6 pairs)
12/0.18
62
1.2
8.2
UL20276 AWG#22
6pair (BLACK)
2 5
(6.56 16.4)
0.2
8
(4 pairs)
40/0.08
105
0.88
6.5
(Note 2)
A14B2339 4P
MR-JHSCBL   M-H
10 to 50
(32.8 to 164)
0.2
12
(6 pairs)
40/0.08
105
0.88
7.2
(Note 2)
A14B2343 6P
2 5
(6.56 16.4)
0.2
8
(4 pairs)
40/0.08
105
0.88
6.5
(Note 2)
A14B2339 4P
Encoder cable
MR-ENCBL   M-H
10 to 50
(32.8 to 164)
0.2
12
(6 pairs)
40/0.08
105
0.88
7.2
(Note 2)
A14B2343 6P
Communication
cable
MR-CPCATCBL3M
3 (9.84)
0.08
6
(3 pairs)
7/0.127
222
0.38
4.6
UL20276 AWG#28
3pair (BLACK)
MR-J2HBUS   M
MR-J2HBUS   M-A
20
(10 pairs)
6.1
UL20276 AWG#28
10pair (CREAM)
Q172J2BCBL   M(-B)
Bus cable
Q173J2B CBL   M
0.5 to 5
(1.64 to 16.4)
0.08
14
(7 pairs)
7/0.127
222
0.38
5.5
UL20276 AWG#28
7pair (CREAM)
Note 1. d is as shown below.
d
Conductor Insulation sheath
2. Purchased from Toa Electric Industry
3. Standard OD. Max. OD is about 10% greater.