1. FUNCTIONS AND CONFIGURATION
1.3 Servo amplifier standard specifications
Servo amplifier
MR-J2S-
Item
10B 20B 40B 60B 70B 100B 200B 350B 500B 700B 11KB 15KB 22KB 10B1 20B1 40B1
Voltage/frequency
3-phase 200 to 230VAC,
50/60Hz or 1-phase 230VAC,
50/60Hz
3-phase 200 to 230VAC, 50/60Hz
1-phase 100 to
120VAC 50/60Hz
Permissible voltage
fluctuation
3-phase 200 to 230VAC:170
to 253VAC
1-phase 230VAC: 207 to
253VAC
3-phase 170 to 253VAC
1-phase 85 to
127VAC
Permissible frequency
fluctuation
Within  5%
Power supply capacity
Refer to section 11.2
Pow
er su
ppl
y
Inrush current
Refer to section 11.5
Control system
Sine-wave PWM control, current control system
Dynamic brake
Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal
relay), servo motor overheat protection, encoder fault protection, regenerative fault protection,
undervoltage, instantaneous power failure protection, overspeed protection, excessive error
protection
Structure
Self-cooled, open (IP00)
Force-cooling, open
(IP00)
External
Self-cooled,
open(IP00)
[ ] 0  to  55 (non-freezing)
In
operation [ ] 32 to  131 (non-freezing)
[ ]
20 to  65 (non-freezing)
Ambient
temperature
In storage
[ ]
4 to  149 (non-freezing)
In operation
Ambient
humidity
In storage
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m (3280ft) above sea level
5.9 [m/s
2
] or less
En
vi
ro
n
m
en
t
Vibration
19.4 [ft/s
2
] or less
[kg] 0.7
0.7
1.1
1.1
1.7
1.7
2.0
2.0
4.9
7.2
16
16
20
0.7
0.7
1.1
Mass
[lb] 1.5
1.5
2.4
2.4 3.75 3.75 4.4
4.4 10.8 15.9 35.3 35.3 44.1 1.5
1.5
2.4