Sony SIR-3400H User Manual

Page of 156
18-2
 (E)
SIR-3400H / SIR-3032i / SIR-3032W
18-2. Error Code
When the recording unit malfunctions during diagnostics, calibration, recording or playback operation, the
error code is displayed on the LCD screen. Take the appropriate measure based on the table below.
When using the recorder in a dusty surrounding, the data could not be played back (or verified during
recording) and also an error code is displayed. In such a case, perform a play back inside a room. If the error
code does not disappear after the appropriate measure has been taken or if the displayed error code is not
listed in this manual, contact service engineer.
-HDD-
EH03
0C01
Drive 1 write retries have exceeded the designated limit
0C02
Drive 2 write retries have exceeded the designated limit
1101
Drive 1 read retries have exceeded the designated limit
1102
Drive 2 read retries have exceeded the designated limit
3001
Drive 1 format is not correct
3002
Drive 2 format is not correct
EH04
0001
Hard disk not installed in drive 1
0002
Hard disk not installed in drive 2
4401
Drive 1 is faulty
4402
Drive 2 is faulty
EH90
0001
Formatting of drive 1 failed
0002
Formatting of drive 2 failed
EH91
No TOC found
EH92
An invalid TOC was detected.
EH93
Communication error occurred on HDD board
EH95
Error occurred in peripherals
File system error
IDE controller error
StarFabric control error
PCI control error
EH96
An unknown error occurred
-ADA-
EA20
00xx
A/D calibration error occurred. xx is the channel.
EA30
00xx
D/A calibration error occurred. xx is the channel.
EA60
ADA flash memory error
0001
CAL data was not found
0002
Unable to access
EA70
Measuring unit ID error
EA80
ADA board error
EA90
DMA timed out in REC
EA91
DMA timed out in PB
-Power Supply/
EP03
Power failure
Battery-
EP10
Battery voltage is low
-Communication-
Ed50
Communication error occurred between the IF board and ADA
board
Ed60
Communication error occurred between the DSP board and ADA
board
Ed70
Communication error occurred between the IF board and DSP
Ed80
Telnet communication error
ES30
Error occurred between DPR board and DR board
ES40
Error occurred between DPR board and IF board
ES50
Error occurred between DR board and IF board
-Synchronizing-
EX30
Sync Setting error/cable error
EX31
Sync No target/sync playback data
EX32
Sync Recording/playback error
EX33
Sync target is recording alone