Sony SIR-3400H User Manual

Page of 156
 (E) 
(3)
SIR-3400H / SIR-3032i / SIR-3032W
Caution
Please read carefully the following precautions prior to use. These precautions will
prevent your data on recording media from being damaged or lost.
Condensation
In the default settings, the condensation sensor on this unit is set to off.
(1) Always turn the condensation sensor on under conditions where condensation may form easily such as
when the temperature around the recording unit goes from a low to high temperature.
(2) To prevent damage to data in environments where condensation tends to occur, be sure to always eject
the recording media after using the recording unit, and then press the POWER switch to turn off the
power.
<Reference> (Section 7-2-2)
Off : Condensation is not detected. If condensation occurs the recording media and data may become damaged.
On : Condensation is detected when the unit’s power is turned on to protect the recording media and data
from being damaged.
Warming Up/Cooling Down
When the temperature inside the unit is too high or too low, the unit displays one of the following messages
and the unit is automatically cooled down or warming up. The unit cannot be operated until the temperature
reaches proper level and the message on LCD display disappears.
LCD message
Recording unit status
Remarks
Low Temp Warming Up
Internal temperature < 5 
dC
Displayed until the internal temperature is
dC or higher
High Temp Cooling Down 70 
dC < Internal temperature
Displayed until the internal temperature is less
than 70 
dC
Overwrite
Once overwritten, the previously recorded data after the point where the overwriting ends cannot be reproduced
(see section 2-5).
<Reference> (Section 8-2-3)
Overwriting is prohibited in the default settings.
To cancel the overwrite protection, set the Overwrite option under Utility_Global Setup Menu_Function to
On in the LCD screen.
In an attempt of overwriting, a message “Overwrite?” will appear on the LCD of the recording unit. If you
wish to overwrite the old data, press FWD key with REC key pressed down.
Power Switch
When turning off the unit completely, first confirm that the ACCESS lamp is out and then turn off the
POWER switch on the rear of unit.