Figure 98.  CM9760-REL Configuration
Table L.  CM9760-REL Settings
Term
Definition
Baud Rate
Set the baud rate according to the External Relay device settings.
Parity
Set the parity according to the External Relay device settings.
COM Port
This is the COM port on the viewstation that the relay unit is connected to.
Frame Address
This should be set with the default values of 0.
Default Latch Time (sec)
The minimum time that is detected by the relay unit. This sets the latch time for all the relay
ports.
Relay
Define the relay port number that you want to change. The first port on the relay unit is 0.
Latch Time (sec)
The minimum time that is detected by the relay unit for the specific port.
Add
Set the new latch time for the specific port.
Remove
Set the default latch time for the specific relay port.
7.
Set the baud rate to 9600 and the parity to Even.
8.
Enter the COM port that the relay unit is connected to on the viewstation.
9.
Click OK.
10. Click Test.