CHAPTER 7  ALARMS
The accompanying diagram (
Picture 7-2
), along with your alarm’s manual should be 
consulted to ensure proper connection.
• Normal open or Normal close type
• Parallel connect COM end and GND end of the alarm detector (Provide external power to 
the alarm detector).
• Parallel connect the Ground of the combo DVR and the ground of the alarm detector.
• Connect the NC port of the alarm sensor to the combo DVR alarm input(ALARM)
• Use the same ground with that of combo DVR if you use external power to the alarm device.
PICTURE 7-2
+12V
GND
COM
PC
GND
ALARM
Alarm input public end should jump out with device power end.
Alarm Device Connection Terminal
Alarm Device
Connection Terminal
+12V
GND
Relay Specification
Model: 
JRC-27F
Material of the contact 
Silver 
Rating (Resistance Load)
Rated switch capacity 
30VDC 2A, 125VAC 1A 
Maximum switch power 
125VA 160W 
Maximum switch voltage 
250VAC, 220VDC 
Maximum switch currency 
1A 
Insulation 
Between contacts with same polarity  1000VAC 1minute 
Between contacts with different 
polarity 
1000VAC 1minute 
Between contacts and winding 
1000VAC 1minute 
Surge voltage 
Between contacts with same polarity  1500V (10×160us) 
Length of open time 
3ms max 
Length of close time 
3ms max 
Longevity 
Mechanical 
50×106 times (3Hz) 
Electrical 
200×103 times (0.5Hz) 
Temperature 
-40°C ~+70°C (-40°F to +158°F)
7.2 ALARM OUTPUT
The alarm output port should not be directly connected to a higher power load (greater than 
1A) to avoid high current which may damage the relay. Use the co-contactor to establish the 
connection between the alarm output port and the load.
• 2 way relay alarm output (NO contact). Provides external power to external alarm device.
• To avoid overloading, please read the following relay parameters sheet carefully. 
• RS485 A/B cable is for the A/B cable of the PTZ camera.