Speco Technologies 4TH User Manual

Page of 175
User’s Manual 
DVR-4TH/8TH/16TH Series 
SPECO TECHNOLOGIES 07/10
 
110 
5.6.5.3   Alert IP 
The Alert IP must match the IP address of the computer. 
 
5.6.5.4   Alert Port 
The ports for both DVR and the CMS Alert must be the same
 
5.6.5.5   Alert Interval 
To define the time interval (1 to 255 seconds) between each alive message. 
 
5.6.6 
Event Full Screen 
This function allows the unit to display the alarm channel in full screen size 
when an alarm is triggered.   
 
Select <None> to enable this function; select <Main> to display the alarm 
channel on Main Monitor when an alarm is triggered; select <Call> to display 
the alarm channel on Call Monitor; and select <Both> to display the alarm 
channel on both Main Monitor and Call Monitor. 
 
5.6.7  
Event Duration 
This item determines the duration of the buzzer and Alarm Out relay function 
after an alarm is triggered. The available event duration range is from 5 
second to 999 seconds.   
 
5.6.8   
Per Channel Config 
This menu is used to set the Video Loss Detect, Motion Detect and Alarm In / 
Out function for each channel. The menu is displayed as below.   
 
Per Channel Config 
Channel Select 
Video Loss Detect 
Motion Detect 
Detection Config 
Alarm In 
Alarm Out 
Digital Deterrent-Day   
Digital Deterrent-Night 
Digital Deterrent-Weekend 
CH01 
OFF 
OFF 
 
OFF 
None 
OFF 
OFF 
OFF