Lincoln Electric SVM204-A User Manual

Page of 98
OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The  welding  arc  is  “cold”  or  weld
performance  is  poor.    Engine
operates  normally  and  auxiliary
output is normal.
1. The  weld  boost  circuit  breaker
may  have  tripped.    This  circuit
breaker is a small button on the
bottom  of  the  control  box,  not
far from the positive weld output
terminal.
2. Check 
the 
weld 
cables,
electrode  holder,  and  work
clamp.    Try  welding  with  a
known  good  set  of  short,
adequately sized cables.
3. The  battery  may  be  low  or
defective.
4. The  welding  electrode  may  be
wet or contaminated.  Try using
a fresh dry welding electrode.
1. Perform  the  Engine  RPM
2. The  brushes  and  slip  rings
may be worn or faulty.  Perform
the  brush  and  slip  ring
service procedure
,
3. Perform  the  battery  and
4. Perform  the  weld  boost
TROUBLESHOOTING AND REPAIR
F-11
F-11
OUTBACK® 185