Sony MAV-555SS User Manual

Page of 94
Chap
ter
 5
B
a
s
ic
 F
u
n
c
tion
s
 of
 Eac
h
 Mod
e
5-4 Basic Operations with DTR+Panel and DTR+DTR Modes
5-3 (E)
1
While holding the SHIFT key on the Control Panel, 
press B1 (Unload).
2
Turn the MULTI CONTROL knob to select the next 
material to play, and press B1 (Load).
Note
Depending on the settings for the Control Panel, Step 1 
may not be necessary.
Please refer to the BKMA-505 Control Panel Operating Manual for 
details.
5-3-3 EE Signal Selection
In panel mode, when EE signal output has been specified 
for each playback port, it is possible to specify the 
recording port for which the EE value is to be output.
In order to make this specification, hold down the PORT 
SELECT button that corresponds to the target playback 
port, and then press the PORT SELECT button for the 
recording port for which the EE value is to be output.
• While the PORT SELECT button for a recording port is 
pressed, that EE signal is output.  When the PORT 
SELECT button for that recording port is released, the 
output returns to the PB picture.
• Subsequently, if the EE picture output specification is 
made for this playback port, the input signal for the 
recording port that was specified by the initial operation 
is output as the EE picture.
Note
Combinations of ports that can be used with EE operation 
are as indicated by the circles in the table below.
(Operation Example)
Outputting the R2 port signal when the EE specification is 
made for the P1 port:
1
While holding down the P1 key, press the R2 key.
While the R2 key is held down, the R2 input signal is 
output to P1.
2
Press the R2 key.
The display returns to the P1 PB picture.
Subsequently, if the EE specification is made for the 
P1 port, the input signal for the R2 port is output as 
the P1 EE signal.
Note
In Expansion menu item REFERENCE SELECT (menus 
349 to 351), when the recording port standard signal is set 
to “input video”, the EE picture is not output.
For details about the setup menu, refer to Section 3-4, “Setup” (page 
3-18)
.
5-4 Basic Operations with DTR+Panel and DTR+DTR 
Modes
In DTR+Panel mode, the R1 and P1 ports are controlled 
through the DTR-3000, while the other ports are 
controlled through the control panel or an external device.  
In DTR+DTR mode, R1/P1 and R2/P2 are each controlled 
separately through two DTR-3000s.
5-4-1 Initial Setup for DTR+Panel 
and DTR+DTR Modes
Before using the DTR+Panel and DTR+DTR modes, 
confirm and set up the following:
(1) The DTR-3000 version connected to this unit must 
be CP:V01.30, VS:V01.20 or later.
(2) The DTR-3000 must be set to the 
DISK:INDIVIDUAL mode. 
(3) The DTR-3000 recording time should be set on this 
unit.
(4) Whether or not loop recording is used, it should be 
set on this unit.
(5) Whether or not partial save is performed should be 
set on this unit.
Please contact your supplier or Sony representative if you 
require more details about (1) and (2) above.
For more details on (3) and (4) above, please refer to the 
following operating information.
Setting the Recording Time from the DTR-
3000
1
Set DTR-1 (and DTR-2) in LIVE DURATION (menu 
034) on the basic menu to the desired time.
Playback port
P1
P2
P3
 Recording port
R1
O
O
O
R2
O
O
R3
O