Sony MAV-555SS User Manual

Page of 94
Chap
ter
 5
B
a
s
ic
 F
u
n
c
tion
s
 of
 Eac
h
 Mod
e
5-5 Basic Operations in BVE Mode
5-9 (E)
When the P1 key was pressed
The signal supplied to the R1 port is output in the EE status 
when the monitor output is an RP port playback signal, or 
when PB/EE has been specified.
Audio volume and video process level at the meter panel 
apply to the playback signal.
After pressing the P1 key, perform REMOTE setup of the 
RP port. REMOTE mode 
5-5-7 Pre-roll Time
When using this unit as the player during DMC editing, 
the setting should be at least five seconds.
Also, with DMC editing, the insertion point may be 
displaced by one frame.
5-5-8 File Backup Function
If the power to the MAV-555SS is accidentally cut while 
you are editing a file, the "Backupxxxxx" file (where 
xxxxx is the date, for example: 05.20-14:00) is 
automatically created. Therefore, if this happens and the 
edited file is deleted, you can continue editing using the 
backup file. However, if the edited file is unloaded before 
the power is cut, backup is not possible. Further, because 
the cut point information is not saved along with the 
backup file, you cannot perform cut jumps or trim cuts in 
this file.
You can unload files from the MAVE-D555 and BKMA-
505.
For details about unloading files, refer to the MAVE-D555 and 
BKMA-505 operation manuals.
5-5-9 Editing-Related Error 
Messages
There are some unique editing function-related errors 
which may occur in BVE mode that do not exist in other 
modes.  These error messages and their remedies are 
described below.
[Cut Entry Full]
In BVE mode, cut information for the file being edited 
is stored internally.  Although this information cannot be 
used in linear editing, it can be used as cut information 
for nonlinear editing when the MAVE-F555 is 
connected.
There is a limit on the number of cuts per file.  The [Cut 
Entry Full] error appears when this limit has been 
reached, and indicates that the file in question cannot be 
edited any further.
Remedy:
• When the above error is generated, follow the 
instructions that are provided in the dialog box that 
appears on the control panel.  Doing so will clear the 
cut information for that file, making further editing on 
the file possible.
• This error can be avoided by performing certain 
operations through the MAVE-F555.  For details, refer 
to the “Error Message List” in the appendix in the 
MAVE-F555 operation manual.
[Edit Entry Full]
The internal area where cut information is stored limits 
the number of files that can be stored.  The [Cut Entry 
Full] error appears when this limit has been reached, and 
indicates that no more files can be created for editing.  
Because an internal temporary file is created when 
editing through the RP port, editing is no longer possible 
once this error has been generated.
Remedy:
• When the above error is generated, follow the 
instructions that are provided in the dialog box that 
appears on the control panel.  Doing so will clear the 
internal cut information area, making further file 
creation and editing possible.
• This error can be avoided by performing certain 
operations through the MAVE-F555.  For details, refer 
to the “Error Message List” in the appendix in the 
MAVE-F555 operation manual.
[Rec Inhibit]
This error is generated if an attempt was made to record 
or edit while the recording port or RP port was in the 
“Rec Inhibit” state, or an attempt was made to record or 
edit a file with file protection on.
Remedy:
Cancel “Rec Inhibit” or file protection in order to record 
or edit.
[Material Entry Full]
The MAV-555SS material management information is 
full; no files can be created.
Remedy:
Unneeded files are deleted.
[Nearly Rec Stop]
When editing or recording a collection file in BVE 
mode, a four-minute area is allocated on the HDD; then, 
as recording continues, when two minutes of this 
allocated area is used up, enough area for two more 
minutes is allocated. This operation repeats as recording 
continues.  This error occurs when the area for two 
additional minutes cannot be allocated because the disk 
is full.   Once this error is generated, recording/editing 
stops after two minutes.
Remedy:
• Recording/editing can continue further even after this 
error is generated if you delete any unnecessary files 
within two minutes of the moment when this error was 
generated.