Chapter 2. Hardware Description 
 
3. Rear Port Specification and Connection Examples 
Page
 
26 
 
 
Optional Alarm Sensor Extension Box 
There is optional Alarm Sensor Extension Box that connects to RS-232 port provided in our DVR unit.  
 
 
① Power switch 
② Power adaptor connector 
③ RS-232 port (Port connected to the system) 
④ Sensor input (1~16) 
⑤ Normal Open alarm output : 1~16 
⑥ Normal Close alarm output : 1~16 
 
Figure 11 Connection Example of Extension Box 
Sensor 1~16 inputs functions same as the S1~S4 inputs (see next section in 10-way terminal Block).  
Difference is that every port is issued with its own ground connection located right below. Additionally 
there are 16 NO (Normally Open) dry contact points with dedicated ground and 16 NC (Normally Closed) 
dry contact point with dedicated ground per points.  These NO, NC points are used in Access control 
integration.