Specification for 10-Way terminal block 
Rated current: 8A 
Contact resistance: 20m 
Insulation resistance: 5000M/1000V 
Withstanding Voltage: AC1500V/1Min 
Wire range: 18AWG 1mm² 
Mechanical 
Temp. Range: -40ºC~+105ºC 
MAX Soldering: +250ºC for 5 Sec. 
Strip length: 5-6mm 
Alarm Out Voltage: 5vt 
[Please refer to the Figure 1 (4ch Model), Figure 2 (9ch Model), Figure 3 (16ch Model) item marked “⑪” 
PTZ, Sensor, Alarm Out Port]. 
RS-485 Connections 
The RS-485 ports are used to connect external PTZ cameras to the DVR.   There is single available port 
with this DVR.  External controllers may be used, however you will not have the ability to control the PTZ 
cameras remotely if you do so.   
There are single RS-485 communications ports, these ports are used to connect external PTZ camera 
controllers.   
 
Figure 14 10-Way terminal block 
Warning 
“S1~S4” port emits +5 volt current out 
from its ports. Some alarm panels may be 
damaged if improper voltages are 
introduced.  Please consult your alarm 
panel documentation for application 
requiring such connection.