In order to allow users to specify the local network IP address  and port number in the filter rules with SUA 
connections, the TCP/IP filter function has to be executed before SUA for WAN outgoing packets and after the 
SUA for WAN incoming IP packets. But at the same time, the Generic filter rules must be applied at the point 
when  the  ZyXEL  Device  is  receiving  and  sending  the  packets;  i.e.  the  ISDN  interface.  So,  the  execution 
sequence has to be changed. The logic flow of the filter is shown in Figure 1 and the sequence of the logic flow 
for the packet from LAN to WAN is:   
 
LAN device and protocol input filter sets.   
 
WAN protocol call and output filter sets.   
 
If SUA is  enabled, SUA converts the source  IP address  from  192.168.1.33 to  203.205.115.6 and 
port number from 1023 to 4034.   
 
WAN device output and call filter sets.   
The sequence of the logic flow for the packet from WAN to LAN is:   
 
WAN device input filter sets.   
 
If SUA is enabled, SUA converts the destination IP address from 203.205.115.6 to 92.168.1.33 and port 
number from 4034 to 1023.   
 
WAN protocol input filter sets.   
 
LAN device and protocol output filter sets.   
 
Generic
  and 
TCP/IP  (and  IPX)
  filter  rules  are  in  different  filter  sets.  The  SMT  will  detect  and  prevent  the 
mixing of different category rules within any filter set in Menu 21. In the following example, you will receive 
an error message 
'Protocol and device filter rules cannot be active together'
 if you try to activate a TCP/IP (or 
IPX) filter rule in a filter set that has already had one or more active Generic filter rules. You will receive the