Aastra Telecom C53I User Guide

Page of 602
Operational, Basic, and Advanced Parameters
41-001160-00, Rev 01  Release 2.0
A-5
Configuration Parameters
Appendix A
Operational, Basic, and Advanced Parameters
The following sections provide the configuration parameters you can configure on 
the IP phone. Each parameter table includes the name of the parameter, a 
description, the format, default value, range, and example. The table also provides 
the method for which the parameters can be configured (IP phone UI, Aastra Web 
UI, or configuration files).
Network Settings
Parameter – 
dhcp
DHCP
(in Web UI)
IP phone UI
Options->Network Settings
Aastra Web UI
Advanced Settings->Network->
Basic Network Settings
Configuration Files
aastra.cfg, <mac>.cfg
Description
Enabling DHCP will populate most of the network information. The DHCP 
server should serve the network information that the IP phone requires. If 
the IP phone is unable to get any required information then it should be 
entered manually. Parameters affected: ip. Use "0" to disable DHCP and 
"1" to enable DHCP.
Format
Integer
Default Value
1
Range
0 or 1
Example
dhcp: 1
Parameter – 
ip
Ip Address
(in Web UI)
IP phone UI
Options->Network Settings
Aastra Web UI
Advanced Settings->Network->
Basic Network Settings
Configuration Files
aastra.cfg, <mac>.cfg
Description
This parameter assigns a static IP address to the IP phone device.
Format
IP address
Default Value
0.0.0.0
Range
Not Applicable
Example
ip: 192.168.0.25